Heat-Flex® 3500 vs. 7000 vs. AEB: Which Thermal Insulative Coating Is Right for Your Application?
This guide breaks down Heat-Flex® 3500, Heat-Flex® 7000 and Heat-Flex® AEB side by side so you can match the right product to your application.
Summary
Corrosion under insulation (CUI) has long been treated as an unavoidable cost of doing business in the process industries. Traditional mineral wool and steel cladding systems trap moisture against steel substrates, and that moisture—combined with oxygen and electrolytes—quietly destroys piping and storage vessels from the outside in. The damage is invisible until it isn't, and by then, the remediation bill is significant.
Sherwin-Williams developed the Heat-Flex® line of thermal insulative coatings (TICs) specifically to address this problem, beginning in 2015 with a series of products designed to protect pipes and storage vessels from corrosion occurring underneath mineral-based insulation and steel cladding. Each generation improved on the last in thermal performance and film build. But the three products serve different use cases, and choosing the right one depends on your operating temperature, insulation requirements and whether eliminating CUI entirely is the goal.
What to expect:
Heat-Flex® 3500: The First-Generation TIC
Heat-Flex® 3500 was designed primarily to reduce surface temperatures on pipes and storage vessels, protecting plant personnel from burns. This allowed operators to forgo cladded insulation systems and protective caging for assets operating up to 350°F (177°C). It applies at 15-20 mils DFT per coat, with six to ten coats for a typical application. Its thermal conductivity of 0.097 W/m·K reflects its role as a personnel protection coating. It uses ceramic and silica microspheres as insulative pigments.
Heat-Flex® 7000: The Second Generation
Heat-Flex® 7000 also addressed personnel protection but introduced additional benefits. It added notable solar heat reflectivity, which minimizes solar radiant heat gain inside coated assets so their contents remain at lower temperatures and encounter less vaporization loss. It also provided sufficient process heat insulation—with just a coating and no external insulation system—to allow assets operating up to 350°F (177°C) to forgo cladded insulation systems altogether. Without any insulation on top of an asset, the threat of CUI is eliminated. This material required just one or two coats at a higher 40-100 mils DFT to offer this protection, with thermal conductivity of 0.065 W/m·K. However, its process heat retention was limited compared to traditional insulation, limiting its use to select plant assets and select cases where operators were willing to increase process heat to accommodate the insulative difference.
Heat-Flex® AEB: The Third Generation
Launched in spring 2025, Heat-Flex® AEB (Advanced Energy Barrier) took process heat retention to another level and removed the asset application limitations of earlier generations. It is a single-component, waterborne acrylic coating with significantly improved insulative properties, resulting from enhanced chemistry and a high film build that is double or more than double that of earlier TIC iterations. With a thermal conductivity of 0.043 W/m·K and a DFT range of 50-200 mils per coat, with up to three coats possible, it delivers insulative performance on par with traditional insulation systems. It follows the Sherwin-Williams OMA protocol: Open, Mix, Apply.
See how Sherwin-Williams tests thermal insulative coatings for touch safety and thermal performance, helping protect personnel from hot surfaces while maintaining thermal efficiency.
| Attribute | Heat-Flex® 3500 | Heat-Flex® 7000 | Heat-Flex® AEB |
|---|---|---|---|
|
Attribute
Generation |
Heat-Flex® 3500
First (Good) |
Heat-Flex® 7000
Second (Better) |
Heat-Flex® AEB
Third (Best) |
|
Attribute
Volume Solids |
Heat-Flex® 3500
83% |
Heat-Flex® 7000
75% |
Heat-Flex® AEB
75% |
|
Attribute
VOC |
Heat-Flex® 3500
<50 g/L |
Heat-Flex® 7000
<50 g/L |
Heat-Flex® AEB
<50 g/L |
|
Attribute
DFT Range Per Coat |
Heat-Flex® 3500
15-20 mils |
Heat-Flex® 7000
40-100 mils |
Heat-Flex® AEB
50-200 mils |
|
Attribute
Typical Coat Count |
Heat-Flex® 3500
6-10 coats |
Heat-Flex® 7000
1-2 coats |
Heat-Flex® AEB
1-3 coats |
|
Attribute
Thermal Conductivity |
Heat-Flex® 3500
0.097 W/m*K |
Heat-Flex® 7000
0.065 W/m*K |
Heat-Flex® AEB
0.043 W/m*K |
|
Attribute
Insulative Pigments |
Heat-Flex® 3500
Ceramic and silica microspheres |
Heat-Flex® 7000
Aerogel and ceramic microspheres |
Heat-Flex® AEB
Aerogel and ceramic microspheres |
|
Attribute
Primary Purpose |
Heat-Flex® 3500
Personnel burn protection + surface temp reduction |
Heat-Flex® 7000
Personnel protection + solar heat reflectivity |
Heat-Flex® AEB
Replace traditional jacketed insulation + eliminate CUI |
|
Attribute
CUI Elimination |
Heat-Flex® 3500
Partial (reduces but doesn't fully replace cladded systems) |
Heat-Flex® 7000
Yes, for select assets |
Heat-Flex® AEB
Yes, for all applicable assets up to 350°F |
|
Attribute
Max Operating Temp |
Heat-Flex® 3500
350°F (177°C) |
Heat-Flex® 7000
350°F (177°C) |
Heat-Flex® AEB
350°F (177°C); excursions to 400°F (204°C) |
|
Attribute
Primary Competition |
Heat-Flex® 3500
Other TICs |
Heat-Flex® 7000
Other TICs; standoff shields/caging |
Heat-Flex® AEB
Other TICs; traditional jacketed insulation (foam, mineral wool, etc.) |
Key insight: Thermal conductivity is the most telling number in this table. AEB's 0.043 W/m*K is the lowest of the three, meaning it transfers less heat through the coating film than either earlier generation. That is the basis for its ability to serve as the sole means of insulation for applications operating at or below 350°F (177°C).
Which Heat-Flex® Product Is Right for Your Application?
The right product depends on what problem you're trying to solve. Here's a practical decision framework.
Choose Heat-Flex® 3500 if:
- Your primary concern is reducing surface temperatures to protect personnel from burns per OSHA guidelines (ASTM C1055)
- You are working on assets where a multi-coat system can be used primarily for personnel protection, and broad process heat retention is not the main requirement
- Your application operates up to 350°F (177°C) and does not require full insulation replacement
Choose Heat-Flex® 7000 if:
- You need personnel protection plus solar heat reflectivity for outdoor storage vessels
- Reducing vaporization loss in storage assets is a priority
- You want to eliminate CUI on select assets where the insulation requirement does not demand the broader heat-retention capability of AEB
- Your application involves insulation requirements that do not demand full replacement of a traditional jacketed system
Choose Heat-Flex® AEB if:
- You need to replace a traditional mineral wool and steel cladding system entirely
- Eliminating CUI is the primary objective
- Your process requires temperature maintenance at or below 350°F (177°C), with excursions to 400°F (204°C)
- You want a single-component system with no mandatory topcoat, where unused material can be resealed and used on future applications
- You are working on piping, valves, storage tanks, or pressure vessels in chemical processing, oil and gas, biofuel, water/wastewater, food and beverage, pharmaceutical, or semiconductor environments
Using spray-applied thermal insulative coatings (TICs) on assets like process vessels enables facilities to eliminate the need for physical barriers or cladded insulation systems.
Spray-applied thermal insulative coatings (TICs) minimize burn hazards to personnel on hot operating assets. They can also help maintain internal process temperatures, such as on this boiler room pipe.
Key Takeaways
- All three products share the same VOC profile (<50 g/L) and operate up to 350°F (177°C), but they differ significantly in thermal conductivity, film build and intended use case.
- Heat-Flex® 3500 is suited for personnel protection on assets where process heat retention is not the primary driver.
- Heat-Flex® 7000 adds solar reflectivity and stronger insulative performance, with CUI elimination possible on select assets.
- Heat-Flex® AEB is the only product in the line capable of fully replacing traditional jacketed insulation systems, with thermal conductivity of 0.043 W/m*K and a DFT range of 50-200 mils per coat.
- Traditional mineral wool insulation loses thermal efficiency as moisture accumulates. Even a small amount of water intrusion can significantly reduce the thermal performance of 2-inch mineral wool, dropping efficiency from more than 90% to under 55% at just 6.5% water by volume. Heat-Flex® AEB maintains consistent thermal efficiency of 73-78% throughout its service life.
- AEB can be applied to hot assets at surface temperatures up to 300°F (149°C), enabling many processes to keep operating during the application process.
Select the Right Heat-Flex® Thermal Insulative Coating with Help from Sherwin-Williams
Choosing between Heat-Flex® 3500, 7000, and AEB comes down to how far you need to go—whether that’s basic personnel protection, improved thermal efficiency, or fully eliminating corrosion under insulation (CUI). Each product serves a clear purpose, but selecting the right one ensures long-term performance, lower maintenance costs, and more reliable operations.
If your goal is to move beyond managing CUI and start eliminating it altogether, newer-generation solutions like Heat-Flex® AEB offer a compelling path forward. If you’re still unsure which coating is best for your application, Sherwin-Williams can help you evaluate your assets, operating conditions, and performance requirements to implement the right coating system with confidence.
For specification support and technical assistance, contact Sherwin-Williams today.
Discover More
Industry Expertise and Innovation
See how we help customers find customized solutions for their project and application challenges.
News
March 28, 2024
Heat-Flex® 7000 Earns Gold for Emerging Technology at Global Tank Storage Awards
Energy Resources
Explore our knowledge base on all things coatings and linings for Energy.
Learn MoreEnergy Newsletter
Subscribe to our Fueling the Future newsletter for essential energy insights.
Subscribe Today